空調(diào)器工作時,制冷系統(tǒng)內(nèi)的低壓、低溫制冷劑蒸氣被壓縮機吸入并壓縮為高壓、高溫的過熱蒸氣后排至冷凝器;同時室外側(cè)風(fēng)扇吸入的室外空氣流經(jīng)冷凝器,帶走制冷劑放出的熱量,使高壓、高溫的制冷劑蒸氣結(jié)為高壓液體。高壓液體經(jīng)過節(jié)流毛細管降壓降溫流入蒸發(fā)器,并在相應(yīng)的壓力下蒸發(fā),吸取周圍熱量,同時室內(nèi)側(cè)風(fēng)扇使室內(nèi)空氣不斷進入蒸發(fā)器的翅片間進行熱交換,并將放熱后變冷的氣體送向室內(nèi)。如此室內(nèi)外空氣不斷循環(huán)流動,達到降低溫度的目的。
When
the air conditioner is working, the low-pressure and low-temperature
refrigerant vapor in the refrigeration system is sucked in by the
compressor and compressed into high-pressure and high-temperature
superheated vapor, which is then discharged to the condenser; At the
same time, the outdoor air sucked in by the outdoor side fan flows
through the condenser, taking away the heat released by the refrigerant,
causing the high-pressure and high-temperature refrigerant vapor to
form a high-pressure liquid. High pressure liquid flows into the
evaporator through a throttling capillary to reduce pressure and cool
down, and evaporates at the corresponding pressure, absorbing
surrounding heat. At the same time, the indoor side fan continuously
enters the fins of the evaporator for heat exchange, and sends the
cooled gas that has been released to the indoor environment. In this
way, the indoor and outdoor air continuously circulates and flows,
achieving the goal of reducing temperature.
熱泵制熱是利用制冷系統(tǒng)的壓縮機冷凝熱來加熱室內(nèi)空氣的,空調(diào)器在制冷工作時,低壓、低溫制冷劑液體在蒸發(fā)器內(nèi)蒸發(fā)吸熱,而高溫、高壓制冷劑氣體在冷凝器內(nèi)放熱冷凝。熱泵制熱是通過電磁四通換向閥來改變制冷劑的循環(huán)方向的,原來制冷工作時作為蒸發(fā)器的室內(nèi)盤管,變成制熱時的冷凝器,實現(xiàn)制熱的。
Heat
pump heating uses the condensation heat of the compressor in the
refrigeration system to heat indoor air. During the refrigeration
operation of the air conditioner, low-pressure and low-temperature
refrigerant liquids evaporate and absorb heat in the evaporator, while
high-temperature and high-pressure refrigerant gases release heat and
condense in the condenser. Heat pump heating is achieved by changing the
direction of refrigerant circulation through an electromagnetic
four-way directional valve. Originally used as an indoor coil in the
evaporator during refrigeration, it has been transformed into a
condenser during heating, achieving heating.
由于熱泵空調(diào)器是通過吸收室外熱量來制熱的,所以熱泵制熱能力隨室外溫度的變化而變化,一般室外氣溫為0℃時,其制熱量為名義制熱量的80%。室外氣溫為-5℃時,其制熱量為名義制熱量的70%
Due
to the fact that heat pump air conditioners generate heat by absorbing
outdoor heat, the heating capacity of heat pumps varies with changes in
outdoor temperature. Generally, when the outdoor temperature is 0 ℃, its
heating capacity is 80% of the nominal heating capacity. When the
outdoor temperature is -5 ℃, its heating capacity is 70% of the nominal
heating capacity